CWE-1253 · Słabość
Incorrect Selection of Fuse Values
- Abstrakcja
- Bazowa
- Status
- Szkic
- Dodano
- 15 października 2019
- Ostatnia zmiana
- 11 grudnia 2025
Opis
The logic level used to set a system to a secure state relies on a fuse being unblown.
Fuses are often used to store secret data, including security configuration data. When not blown, a fuse is considered to store a logic 0, and, when blown, it indicates a logic 1. Fuses are generally considered to be one-directional, i.e., once blown to logic 1, it cannot be reset to logic 0.
Skutki
Access Control, Authorization
Bypass Protection Mechanism; Gain Privileges or Assume Identity
If the logic used to determine system-security state (by leveraging the values sensed from the fuses) uses negative logic, an attacker might blow the fuse and drive the system to an insecure state.
Availability
DoS: Crash, Exit, or Restart
Confidentiality
Read Memory
Integrity
Modify Memory; Execute Unauthorized Code or Commands
Zapobieganie
Architecture and Design
Logic should be designed in a way that blown fuses do not put the product into an insecure state that can be leveraged by an attacker.
Słabość nadrzędna
Kiedy powstaje
- Architecture and Design
- Implementation
Dotyczy
Not Language-Specific, Not OS-Specific, Not Architecture-Specific, Not Technology-Specific
Uwagi
This entry is still under development and will continue to see updates and content improvements.
Źródła
- Security Failures in Secure Devices — Christopher Tarnovsky
Wpis z katalogu CWE 4.20.